265CS Multi-Parameter Differential Pressure Transmitter


Basic accuracy of 0.1% (optional 0.05%), differential pressure range of 25 Pa to 2 MPa, and static pressure range of 0.6 MPa to 42 MPa (absolute pressure). When connected to an external temperature sensor, online temperature and pressure compensation can be achieved, enabling the measurement of volumetric or mass flow rates for gases or water vapor that require such compensation. Verified overall accuracy; utilizing the MODBUS communication protocol and a remote transmission unit (TRTU), it is suitable for commercial metering applications such as natural gas transmission and steam measurement.

H&B 2000L Series Intervening (Air-Blowing/Liquid-Blowing) System Measurement Device (Air-Blowing Transmitter)


Online plug-and-play replacement is possible; for example, level measurement in degradable-plastic chain-extending and viscosity-enhancing reactors. Fully welded, integrated structure (split design available as an option), with simple installation and maintenance; holistic design ensures anti-blocking and leak-proof performance. Highly versatile and multi-purpose, capable of measuring liquid level, density, interface, as well as pressure and flow under conditions prone to blockage. Suitable for liquid-level measurement in a wide range of complex operating conditions, with simultaneous resistance to high temperature and vacuum (temperature up to 800°C, pressure down to 10⁻³ Pa). Ideal for measuring in highly viscous media (viscosity can exceed 2500 Pa·s) and strongly corrosive environments. Applicable to pressure, liquid-level, and flow measurement in radioactive settings, such as seawater level differentials in nuclear-power-plant pump rooms. The latest fifth-generation gas-blown level transmitter: constant-flow and self-powered pressure stabilization, with a minimum blow-in flow rate of 0–10 L/h, offering high accuracy and excellent stability; equipped with back-blowing and anti-blocking functions. Suitable for liquid-level measurement in any medium prone to crystallization or condensation: includes air-source heating and a gas-blown measurement method that matches the original process fluid (e.g., liquid-level measurement in α-olefin and urea towers).

H&B 2000L Series Intrusive (Air-Blowing, Liquid-Blowing) Measurement System (Air-Blowing – Single-Channel Transmitter)


Online plug-and-play replacement is possible; for example, level measurement in degradable-plastic chain-extending and viscosity-enhancing reactors. Fully welded, integrated structure (split design available as an option), with simple installation and maintenance; holistic design ensures anti-blocking and leak-proof performance. Highly versatile and multi-purpose, capable of measuring liquid level, density, interface, as well as pressure and flow under conditions prone to blockage. Suitable for liquid-level measurement in a wide range of complex operating conditions, with simultaneous resistance to high temperature and vacuum (temperature up to 800°C, pressure down to 10⁻³ Pa). Ideal for measuring in highly viscous media (viscosity can exceed 2500 Pa·s) and strongly corrosive environments. Applicable to pressure, liquid-level, and flow measurement in radioactive settings, such as seawater level differentials in nuclear-power-plant pump rooms. The latest fifth-generation gas-blown level transmitter: constant-flow and self-powered pressure stabilization, with a minimum blow-in flow rate of 0–10 L/h, offering high accuracy and excellent stability; equipped with back-blowing and anti-blocking functions. Suitable for liquid-level measurement in any medium prone to crystallization or condensation: includes air-source heating and a gas-blown measurement method that matches the original process fluid (e.g., liquid-level measurement in α-olefin and urea towers).

H&B 2000L Series Intrusive (Air-Blowing, Liquid-Blowing) Measurement System (Air-Blowing Sensor)


Online plug-and-play replacement is possible; for example, level measurement in degradable-plastic chain-extending and viscosity-enhancing reactors. Fully welded, integrated structure (split design available as an option), with simple installation and maintenance; holistic design ensures anti-blocking and leak-proof performance. Highly versatile and multi-purpose, capable of measuring liquid level, density, interface, as well as pressure and flow under conditions prone to blockage. Suitable for liquid-level measurement in a wide range of complex operating conditions, with simultaneous resistance to high temperature and vacuum (temperature up to 800°C, pressure down to 10⁻³ Pa). Ideal for measuring in highly viscous media (viscosity can exceed 2500 Pa·s) and strongly corrosive environments. Applicable to pressure, liquid-level, and flow measurement in radioactive settings, such as seawater level differentials in nuclear-power-plant pump rooms. The latest fifth-generation gas-blown level transmitter: constant-flow and self-powered pressure stabilization, with a minimum blow-in flow rate of 0–10 L/h, offering high accuracy and excellent stability; equipped with back-blowing and anti-blocking functions. Suitable for liquid-level measurement in any medium prone to crystallization or condensation: includes air-source heating and a gas-blown measurement method that matches the original process fluid (e.g., liquid-level measurement in α-olefin and urea towers).

Nuclear-grade blow-off device


Suitable for measuring multiple variables in various radioactive liquid streams across the nuclear industry. No moving parts; except for the purge gas line, the instrument does not come into contact with the process fluid. Compact, robust, small, and aesthetically pleasing design, facilitating installation and maintenance. Modular design eliminates complex piping and valves, ensuring excellent sealing and low failure rates. All-welded, integrated construction provides superior seismic resistance (as demonstrated in seismic testing of nuclear-safety-class purge gas systems). Highly versatile: a single device can serve multiple applications, allowing users to select one-, two-, three-, four-, or five-pipe purge systems based on their specific needs. Ideal for pressure, level, density, and flow measurement in radioactive environments, including spent fuel reprocessing, uranium enrichment, and seawater level differential measurements in nuclear power plant pump rooms.

Magnetic flap level indicators, magnetostrictive level transmitters, magnetic switches


Magnetic flap level gauges are suitable for level monitoring and indication in a wide range of media, while magnetostrictive level gauges can be used for high-precision continuous measurement of liquid levels and interfaces in various media. They enable safe and reliable level measurement under high-temperature, high-pressure, and highly corrosive conditions, with full-range measurement free of blind zones, prominent display, and intuitive readout. These instruments can be equipped with level switches to provide upper- and lower-limit alarms for liquid level or interface. They can also be fitted with level transmitters that convert level and interface signals into a two-wire 4–20 mA + HART standard signal, enabling remote detection, indication, recording, and control. On-site commissioning and maintenance are unnecessary, ensuring high stability and safety.

H&B265SF Series Integrated Differential Pressure Flow Measurement System


All-welded, integral structure; optional temperature and pressure compensation; optional integrated purging and anti-blocking pressure tapping. Calibration for commercial handover, national metrological certification, and full-series TS certification are available. Comprehensive turnkey solutions are provided, including throttling elements paired with on-site flow sensors tailored to specific operating conditions. Capable of measuring a wide range of special media, including gases, liquids, steam, and liquid-solid two-phase mixtures. Multi-parameter transmitters can measure various parameters, such as volumetric flow rate and mass flow rate of air, gases, or steam. Explosion-proof certifications: intrinsically safe, flameproof, NEPSI, ATEX, FM, and others. Supports multiple communication protocols: HART/4–20 mA, PROFIBUS-PA, FF, and more.

FXEM4000 Electromagnetic Flowmeter


Power Supply: 220 V AC, 24 V DC, or 3.6 V lithium battery Electrode Types: Standard type, scraper type Electrode Materials: 316L, Hastelloy alloy, titanium, tantalum, platinum–iridium Process Connection Types: Flange, clamp, threaded, welded, DIN 11851/Tri-Clamp (hygienic), etc. Applications: Suitable for measurement in harsh conditions involving pulp, mineral slurry, mud, coal slurry, and low-conductivity media Pipe Size Range: DN15–DN1600; Pressure Rating: PN10–PN40 Conductivity: ≥5 μS/cm; for low-conductivity media: ≥0.5 μS/cm; Accuracy: 0.5% Medium Temperature: Standard version –25°C to 150°C; High-Temperature version up to 200°C Protection Rating: IP67, IP68 (submersible) Optional high- and low-frequency excitation as well as square-wave excitation; Excitation Frequencies: 6.25 Hz, 12.5 Hz, 25 Hz and above, selectable

FVM5000 Vortex Flowmeter


Caliber range: DN15–DN300 Accuracy: ±0.75% (liquids); ±1% (gases and steam) Sensor section: Integral casting of the body; independently designed flow element Process connection type: Standard flange connection Sensor materials: Body made of SCS14A cast stainless steel (equivalent to 316); flow element made of SUS329J1 duplex stainless steel Pressure rating: PN10–PN63, CL150–CL600 Medium temperature: −40°C to 250°C; high-temperature version up to 350°C Protection rating: IP67 Power supply: 24 VDC; dual power supply option of 24 VDC and lithium battery Output: 4–20 mA + HART or pulse/4–20 mA + RS485 (Modbus protocol) + pulse
< 1234 >
搜索历史清除全部记录
最多显示8条历史搜索记录噢~
All
  • All
  • Product Management
  • News and Information
  • Introduction Content
  • Enterprise outlets
  • Frequently Asked Questions
  • Corporate Video
  • Corporate Brochure